닫기

Pure water /Ultra Pure Water plant

Chungam Water Treatment & Engineering Co., Ltd. is a specialized company that provides all solutions for water treatment processe

Pure water treatment and ultrapure water treatment?

Pure Water Treatment

Water from which impurities such as electrolytes, organic matter, microorganisms, and suspended solids in water have been removed using removal methods such as ion exchange, reverse osmosis, and distillation.

Ultra Pure Water Treatment

Ultrapure water is water from which impurities such as electrolytes, organic matter, microorganisms, and suspended solids in water are removed using ion exchange method, reverse osmosis method, U.F. and water manufactured for electronics, pharmaceuticals, chemical industry, thermal power, nuclear power and other uses by more completely removing impurities of dissolved oxygen such as gas

1st Generation (Pre-Treatment + 2B3T + MBP)

Demineralized Water is produced by a process that sequentially removes cations and anions in water using an ion exchange resin.

2nd Generation (Pre-Treatment + RO + MBP)

Pure water is produced by treating reverse osmosis membrane through membrane filtration and passing it through a resin tower in which a strong acid cation resin and a strong basic anion resin are mixed, and removing electrolytes in water

3rd Generation (Pre-Treatment + RO + Electric Resin/EDI)

Reverse osmosis membrane and electric desalination are used to remove ionic components in the water, and a POLISHING UNIT is installed in the final process. Ultra Pure Water is produced by the process to produce ultra pure water by removing TOC, DO, PARTICLE, SiO2, etc.

  • Power PLANT

    1st Generation 2B3T + MBP SYSTEM MODELING

  • DEMI PLANT

    View of 3rd generation R/O + EDI System facility

Go to Business Performance

PROCESS

Comparison table of R/O and high-efficiency R/O

Item Original RO SYSTEM HPRO SYSTEM
Equipment configuration MMF + ACF + RO SYSTEM DUPLEX CATION TOWER+DECARBONATOR
+SAFTY FITELR + HPRO
Recovery rate 75~85% 90~95%
Advantages Low initial investment cost High recovery rate and stable configuration like a no-discharge system
Disadvantages Wastewater generation due to low recovery rate compared to HPRO Higher initial investment cost compared to RO SYSTEM

* Move left and right